Reference data is what you look up rather than calculate, but the lookup still has to be right. This section collects physical constants, absorbance factors, unit definitions, and conversion factors used across the calculators on this site, gathered in one place so you do not have to cross-check three tabs. Values cite their units explicitly and are stated to the precision a bench calculation actually needs.

The reference tables workspace gathers the reference values used across BiomeBench in one place. Each table names the authority behind its values in its provenance section, and source attribution stays a standing content requirement of the site.

Tables hand you a number; the calculators carry that number into a calculation. When a table and a calculator disagree on a value, check the provenance section of the table first. The site treats an unreproducible citation as a content defect, and not as a rounding choice.

The workspaces menu also opens the plate planner and the inventory tracker. All three workspaces run in the browser and keep their state on your side.

The absorbance factors table carries the numbers the quantification tools use: 50 µg/mL per A260 unit for double-stranded DNA, 40 for RNA, and 33 for single-stranded DNA, plus the per-mole factor for oligonucleotides and the typical value for pure protein. The A260/A280 purity ranges sit beside them, so a ratio can be checked against the range for pure dsDNA, ssDNA, RNA, and protein before it is trusted.

The physical constants table holds Avogadro’s constant, the gas constant, the Faraday constant, and the other SI constants a bench calculation reaches for, with values and units stated. The SI prefixes table lists the multipliers from giga down, so a unit step can be checked without leaving the page.

The conversion tables state the factors the calculators apply: common laboratory conversions, concentration expressions, and the serial dilution reference. The normal quantile table lists the z values the sample size calculation uses, including 0.84 for 80 percent power and 1.28 for 90 percent power. The CODIS core STR loci table sits here too, for the inheritance simulator.

Copy a value the same way every time: read the unit first, then the number, then the provenance. The calculator input labels name the unit they expect, so a value copied in the wrong unit fails silently. Significant figures follow the source reading: a value read to two figures does not gain precision by being typed into a calculator.

The tables are read-only reference, not input forms. Nothing typed on this page is stored or sent anywhere, and a value leaves the page only when you carry it into a calculator yourself. If the calculator input expects a different unit than the table states, the unit converter bridges the two before the value is entered.

A value on the page is only as good as its source. Before a number is carried into a calculation, check where it came from: the sources list names the standard or publication behind each table. A value whose source cannot be checked should not be used, and a value remembered from elsewhere should be checked against the table before it is entered.