Serial Dilution: Step-by-Step Protocol
A step-by-step serial dilution protocol using the C1V1 = C2V2 equation, with countable-range rules, common mistakes, and a link to the Serial Dilution Planner tool.
Guides & protocols
21 guides available.
Each guide walks through one lab calculation from start to finish. It shows the formula, the inputs you need, and the steps in the order you carry them out at the bench, then links to the calculator that runs the numbers.
The guides cover the calculations the calculators handle: making dilutions and stock solutions, counting cells with a hemocytometer, preparing PCR reactions, and reading absorbance for protein and nucleic acid concentration. They connect the tools that share a step, so the dilution guide links both the dilution calculator and the serial dilution calculator.
Read a guide when you want the reasoning beside the calculator. Each one states the assumptions and the limits of its formula, so you can tell whether it fits the sample in front of you.
Guides sit beside the reference tables. When a calculation needs a published constant, the guide points to the table that holds it and the source behind it.
A step-by-step serial dilution protocol using the C1V1 = C2V2 equation, with countable-range rules, common mistakes, and a link to the Serial Dilution Planner tool.
The serial dilution formula C1V1 = C2V2 explained with step-by-step derivations, worked examples for two-fold and ten-fold series, and the log-scale meaning of each step.
Comparison of DNA quantification methods: Qubit, Nanodrop, PicoGreen, and UV-Vis spectrophotometry. When to use each, pros and cons, and what the A260 A280 ratio means.
How to calculate molarity from mass, molecular weight, and volume. Worked examples, unit conversions between grams milligrams microliters and molar millimolar micromolar, and common buffer recipes.
CFU per mL calculation from plate counts: formula, the 30 to 300 countable range rule, dilution factor handling, and serial dilution for CFU assays.
How to dilute spirits to a target proof or ABV using the C1V1 = C2V2 equation. Covers proof-to-ABV conversion, volume contraction, temperature correction, and practical steps for home and small-batch mixing.
The hemocytometer formula converts manual square counts into cells per mL. Covers the derivation (cells/mL = count × dilution × 10⁴), a chamber multiplier table, viability calculation, worked examples, and Neubauer chamber assumptions.
A complete hemocytometer protocol: chamber preparation, sample loading, counting rules, trypan blue viability staining, and common errors. Includes a 5-step bench workflow and link to the Hemocytometer Calculator.
How to use the Hemocytometer Calculator: enter your counts, read viability, and turn the viable concentration into the volume to seed. Includes the seeding handoff to the Cell Seeding Calculator.
How to plan a dilution at the bench: when one step is enough, when to dilute in series, and the pipetting mistakes that spoil a dilution. Routes to the Dilution Calculator and the Serial Dilution Planner.
The dilution formula C1V1 = C2V2 derived from mass conservation, with step-by-step worked examples for molar, percent, and fold units, unit conversion tables, and common pitfalls.
How to calculate cell seeding density from viable concentration. Covers suspension and diluent volumes per vessel, confluence targets, passaging split ratios for multi-well plates and flasks, and practical pipetting limits.
How to calculate protein concentration from A280 absorbance. Covers the Beer-Lambert formula c = A × dilution ÷ E, mass versus molar extinction coefficients, worked examples, and common protein coefficients.
Compare primer melting temperature (Tm) calculators: Wallace rule, nearest-neighbor model, GC content, salt concentration, and how IDT, Twist, and NEB estimates differ. Pick the right Tm for your PCR design.
How spectrophotometry works, the Beer-Lambert law, A260/A280 purity ratios, and how to read absorbance measurements at the bench.
How to build a calibration curve, assess linearity with R², apply the Beer-Lambert law in quantitative analysis, and propagate measurement uncertainty through dilutions and calculations.
How to prepare a PCR master mix: the standard 25 µL recipe, scaled totals for 10, 24, and 96 reactions at 10% overage, order of addition, annealing-temperature starting points, and a troubleshooting table.
How to normalize a counted cell suspension to one target concentration before plating: the V_add formula, a worked 96-well example, dead-volume excess, pipetting limits, and how this bench step differs from B-score data normalization.
What the two-means sample size calculator does: the normal-approximation formula, a worked example with 41 replicates per group, the assumptions it rests on, and when to use G*Power instead.
One worked day from count to plate: count a suspension on the hemocytometer, seed 20,000 cells per well, normalize the batch to 100,000 cells/mL, and lay out the 96-well plate map.
One worked plate from primers to plate map: check primer Tm, measure template by A260, scale the 25 µL master mix to 96 reactions at 10% overage, and lay out the 96-well plate map.