Decide the target first
Start from the protocol: the final concentration (C2) and the final volume (V2) you need. Check the stock concentration (C1) on the bottle and confirm both concentrations use the same unit. A mM stock against a µM target is a thousand-fold error before you pipette anything.
Write the three numbers down before you touch a pipette. A dilution planned on paper takes a minute; a dilution redone after a unit slip costs the reagent and the time.
One step or a series?
A single step suits a modest factor. Up to about 100-fold, and with a stock volume of 10 µL or more, one dilution is fast and keeps the error in one transfer.
Go serial when the factor is larger than about 100, or when the stock volume drops below about 2 µL. A series keeps every transfer in a comfortable pipetting range and spreads the error across steps you can check. The Serial Dilution Planner lays out each tube: transfer volume, diluent volume, and concentration per tube.
A serial dilution also earns its place when you need a range of concentrations for an assay, rather than one working solution.
Use this decision table before you start:
| Stock volume V1 | Dilution factor | What to do |
|---|---|---|
| 10 µL or more | 100 or less | Single step. Comfortable. |
| 2–10 µL | Any | Check twice. Small volumes are error-prone. |
| Less than 2 µL | Any | Use a serial dilution. Pipetting below 2 µL is unreliable. |
| Any | More than 100 | Use a serial dilution. One step would need an impractically small stock volume. |
Work it out in three moves
First, solve for the stock volume: V1 = (C2 × V2) / C1. The Dilution Calculator does this for any one unknown from the other three.
Second, work out the diluent: diluent = V2 − V1. V2 is the final total volume, not the diluent volume.
Third, check V1 against your pipette. For example, 5 M stock to 500 mM in 50 mL needs V1 = (500 × 50) / 5000 = 5 mL of stock and 45 mL of diluent. If V1 had come out under 2 µL, plan a series instead.
Pipetting warnings
Small volumes carry the largest error. Below about 10 µL, check the pipette setting twice and consider a larger final volume or a series.
Mix the stock before you take V1, and mix again after you add the diluent. An unmixed stock gives a wrong aliquot; an unmixed dilution gives an uneven working solution.
Match the units on both concentrations. A mM stock against a µM target is off by a factor of 1,000.
Label the tube with the final concentration, the date, and your initials. An unlabelled dilution is a reagent you cannot trust.
Which tool to open
Match the job to the tool:
- One unknown in C1V1 = C2V2: Dilution Calculator
- A whole series, tube by tube: Serial Dilution Planner
- The derivation, unit conversions, and worked examples: Dilution Formula C1V1 = C2V2 guide
- Spirits to bottling proof: Alcohol Dilution guide