What a serial dilution is

A serial dilution starts from a stock solution and makes each new tube by moving a fixed volume into a fixed volume of solvent. The result is a geometric series: each step is the previous concentration divided by the dilution factor.

Each step follows C1V1 = C2V2. The derivation and the worked math live on the Serial Dilution Formula page; this page covers the bench work.

What you need

  • Stock solution of known concentration.
  • Clean tubes or microcentrifuge tubes, one per dilution step plus one for the stock.
  • Solvent or diluent (usually the same buffer or medium the stock is in).
  • Pipette and tips matched to the volumes you are moving.
  • Tube rack and marker for labelling.

Step-by-step protocol

Label one tube per step, plus a stock tube. A ten-fold series from 10^-1 to 10^-6 needs six tubes in addition to the stock.

Add the diluent volume to every tube first. For a ten-fold dilution, add 900 µL of diluent to each tube. For a two-fold dilution, add an equal volume of diluent to each tube.

Mix the stock well, then transfer the aliquot into the first tube. For a ten-fold dilution, move 100 µL of stock into 900 µL of diluent. The first tube is now a 10^-1 dilution.

Mix the first tube well. Then transfer the same aliquot volume from that tube into the next tube of diluent. The second tube is a 10^-2 dilution, one-tenth of the first.

Repeat for every step. Tube n holds a 10^-n dilution of the original stock.

Change tips between steps so carry-over from one tube does not bias the next.

A ten-fold series from a 1 mg/mL stock looks like this:

TubeDilutionConcentrationHow to make it
Tube 110^-10.1 mg/mL (100 µg/mL)100 µL stock + 900 µL diluent
Tube 210^-20.01 mg/mL (10 µg/mL)100 µL from tube 1 + 900 µL diluent
Tube 310^-30.001 mg/mL (1 µg/mL)100 µL from tube 2 + 900 µL diluent
Tube 410^-40.0001 mg/mL (0.1 µg/mL)100 µL from tube 3 + 900 µL diluent
Tube 510^-50.00001 mg/mL (0.01 µg/mL)100 µL from tube 4 + 900 µL diluent
Tube 610^-60.000001 mg/mL (1 ng/mL)100 µL from tube 5 + 900 µL diluent
Step-by-step protocol Step-by-step protocol — 100 µL into 900 µL diluent per step; 1 mg/mL stock to 10⁻⁶, 0.000001 mg/mL in tube 6 1 mg/mL 100 µL 100 µL 100 µL 100 µL 100 µL 100 µL 10⁻¹ 0.1 mg/mL 900 µL 10⁻² 0.01 mg/mL 900 µL 10⁻³ 0.001 mg/mL 900 µL 10⁻⁴ 0.0001 mg/mL 900 µL 10⁻⁵ 0.00001 mg/mL 900 µL 10⁻⁶ 0.000001 mg/mL 900 µL

Worked example: two-fold series for an assay range

You need a two-fold series from a 4 mg per mL stock for a dose-response assay, down to 0.125 mg per mL: 2, 1, 0.5, 0.25, 0.125 mg per mL. That is five dilution steps, or 2^5 = 32-fold overall.

Add 400 µL of diluent to each of five tubes. Transfer 400 µL of stock into tube 1 and mix: 2 mg per mL. Transfer 400 µL from tube 1 into tube 2 and mix: 1 mg per mL. Continue the same transfer down the row.

Tube 5 holds 4 / 32 = 0.125 mg per mL. The Serial Dilution Planner calculates these volumes automatically and flags any transfer below the pipetting floor.

Serial Dilution Planner

Countable range and common mistakes

When you plate from a dilution for a CFU count, aim for 30 to 300 colonies per plate. Below 30 the result is statistically weak; above 300 colonies overlap and the count underestimates the true concentration. Pick the dilution that lands in that window.

Do not skip the mix step. An un-mixed tube gives an uneven cell suspension and a wrong dilution down the whole series.

Do not reuse tips. Carry-over shifts every later tube away from the intended factor.

Do not guess the diluent volume. A ten-fold dilution needs exactly one part sample to nine parts diluent; eyeballing it breaks the series.

After the series

Cap and label each tube with its dilution and the date. Plate from the tube that lands in the countable range; the planner shows the concentration in every tube, so you can pick it before you plate.