What a serial dilution is
A serial dilution starts from a stock solution and makes each new tube by moving a fixed volume into a fixed volume of solvent. The result is a geometric series: each step is the previous concentration divided by the dilution factor.
Each step follows C1V1 = C2V2. The derivation and the worked math live on the Serial Dilution Formula page; this page covers the bench work.
What you need
- Stock solution of known concentration.
- Clean tubes or microcentrifuge tubes, one per dilution step plus one for the stock.
- Solvent or diluent (usually the same buffer or medium the stock is in).
- Pipette and tips matched to the volumes you are moving.
- Tube rack and marker for labelling.
Step-by-step protocol
Label one tube per step, plus a stock tube. A ten-fold series from 10^-1 to 10^-6 needs six tubes in addition to the stock.
Add the diluent volume to every tube first. For a ten-fold dilution, add 900 µL of diluent to each tube. For a two-fold dilution, add an equal volume of diluent to each tube.
Mix the stock well, then transfer the aliquot into the first tube. For a ten-fold dilution, move 100 µL of stock into 900 µL of diluent. The first tube is now a 10^-1 dilution.
Mix the first tube well. Then transfer the same aliquot volume from that tube into the next tube of diluent. The second tube is a 10^-2 dilution, one-tenth of the first.
Repeat for every step. Tube n holds a 10^-n dilution of the original stock.
Change tips between steps so carry-over from one tube does not bias the next.
A ten-fold series from a 1 mg/mL stock looks like this:
| Tube | Dilution | Concentration | How to make it |
|---|---|---|---|
| Tube 1 | 10^-1 | 0.1 mg/mL (100 µg/mL) | 100 µL stock + 900 µL diluent |
| Tube 2 | 10^-2 | 0.01 mg/mL (10 µg/mL) | 100 µL from tube 1 + 900 µL diluent |
| Tube 3 | 10^-3 | 0.001 mg/mL (1 µg/mL) | 100 µL from tube 2 + 900 µL diluent |
| Tube 4 | 10^-4 | 0.0001 mg/mL (0.1 µg/mL) | 100 µL from tube 3 + 900 µL diluent |
| Tube 5 | 10^-5 | 0.00001 mg/mL (0.01 µg/mL) | 100 µL from tube 4 + 900 µL diluent |
| Tube 6 | 10^-6 | 0.000001 mg/mL (1 ng/mL) | 100 µL from tube 5 + 900 µL diluent |
Worked example: two-fold series for an assay range
You need a two-fold series from a 4 mg per mL stock for a dose-response assay, down to 0.125 mg per mL: 2, 1, 0.5, 0.25, 0.125 mg per mL. That is five dilution steps, or 2^5 = 32-fold overall.
Add 400 µL of diluent to each of five tubes. Transfer 400 µL of stock into tube 1 and mix: 2 mg per mL. Transfer 400 µL from tube 1 into tube 2 and mix: 1 mg per mL. Continue the same transfer down the row.
Tube 5 holds 4 / 32 = 0.125 mg per mL. The Serial Dilution Planner calculates these volumes automatically and flags any transfer below the pipetting floor.
Countable range and common mistakes
When you plate from a dilution for a CFU count, aim for 30 to 300 colonies per plate. Below 30 the result is statistically weak; above 300 colonies overlap and the count underestimates the true concentration. Pick the dilution that lands in that window.
Do not skip the mix step. An un-mixed tube gives an uneven cell suspension and a wrong dilution down the whole series.
Do not reuse tips. Carry-over shifts every later tube away from the intended factor.
Do not guess the diluent volume. A ten-fold dilution needs exactly one part sample to nine parts diluent; eyeballing it breaks the series.
After the series
Cap and label each tube with its dilution and the date. Plate from the tube that lands in the countable range; the planner shows the concentration in every tube, so you can pick it before you plate.